AQS
ECtox-CO Carbon Monoxide Gas Device
· Combined with intelligent algorithms it has better adaptability to the environment.
· Higher accuracy in detection and stable zero point.
· With pump, no calibration with CO gas needed.
· New microcircuit design, strong anti-electromagnetic interference ability.
· No temperature and humidity influence.
· RS485 output, 5-12V DC power.
· Stainless steel housing, water and dust proof, anti-corrosion
· The detection range is automatically adjusted to the concentration range of the measured gas, from ppb to higher ppm level.
· Continuously monitors its own fault conditions, Sensor, Pump, Power etc.
· RoHS eco-friendly design.
· Self-monitoring of the sensor function.
Product Overview
The Carbon Monoxide Gas Sensor Device, in combination with the principle of coulometry, delivers a high-precision gas detection technology. The higher the Carbon Monoxide concentration the faster the sensor will be drained. Therefore the sensor lifetime will deteriorate rapidly and more maintenance will be needed. ECtox’s big advantage, while continuously working with a high Carbon Monoxide concentration, is its long lifetime. A pump easily transports the gas to the sensor without the need to calibrate. The sensor can be used for emission measurement, Carbon Monoxide leakage detection and process control. The output signal, RS485 (Modbus), will effortlessly connect with a gas device, DCS, PLC or wireless systems.
Principle
The ECtox device contains an EC Sense solid electrolyte CO gas sensor featuring long lifetime, robustness and selectivity. Based on a specific electrochemical reaction and in combination with a sample pump the device measures Carbon Monoxide concentration in a wide range. The gas reaches the working electrode of the sensor by a certain pump volume, which is always constant. All gas in the offered gas volume will be consumed by the sensor. It creats a signal peak, which is proportional to the Carbon Monoxide concentration in the measuring gas. No calibration is necessary due to the coulometric measuring principe.
The sampling system is good for different densities, the speed of diffusion and convection is usually vslow or depends on the environment, and temperature and different concentration influenced the speed of molecular motion. Sampling System let gas easy going to sensor.
Specification
Principle |
Solid Polymer Electrochemical Technology |
Gas |
Carbon Monoxide Gas |
Range |
0-2000ppm |
Resolution |
0.1ppm |
Accuracy |
± 5% F.S |
Repeatability |
≦ 2% |
Settling time |
It takes 60 minutes for the first power-on to reach measurement stability in the test environment. |
Response time |
Real-time monitoring, data acquisition cycle customized. |
Sensor expected life time |
> 5 years. |
Output |
RS485(Modbus protocol), Baud rate: 9600 |
4Pin Leomo Cable with 10m(Other length by request) |
|
Get data command |
See ECtox protocol document for details |
Working Voltage |
5 - 12V DC |
Maximum Current Consumption |
1A |
Maximum Power Consumption |
5W |
Working Temperature |
-20 ~ +55℃ |
Optimal Working Temperature |
25℃ |
Working Humidity |
(5 ~ 95)% RH non-condensing |
Optimum Working Humidity |
50% RH. |
Temperature and Humidity of the Measured Gas |
-20~+200℃, 5-95% RH non-condensing |
Size |
159 x 43mm |
Weight |
ECtox: 450g, Lemo with 10m cable: 400g |
Warranty |
12 months |
Temperature and humidity sensor data |
Temperature Range: -40 ~ +85℃, Relative error: ± 0.2 ℃ |
Humidity measurement range: 10 - 95% RH. non-condensing, Relative error: ± 2% |
Product Name |
Part Number |
Range |
Resolution |
Carbon Monoxide Gas Sensor Device |
05-ECtox-CO-10000-01 |
0-10000ppm |
1ppm |
05-ECtox-CO-2%-01 |
0-2%vol |
0.01%vol |
|
05-ECtox-CO-10%-01 |
0-10%vol |
0.01%vol |
|
Cable |
02-LEMO-HXT-1423-01 |
10m (Other length by request) |
/ |
Fixed Assembly |
02-ECtox-Fix-C45-01 |
Optional accessories |
/ |